So small, yet so powerful.
T6060 can count on a measurement resolution of 0.1 Pa to 1 bar (0.5 Pa to 6 bar) stable and noise-free, sharing a part of the measurement section implemented on the higher series T8000 and T9000.
Despite being designed as an entry-level tool, the measurement performance is absolutely comparable to those of the rest of the ForTest range.
Advanced measurement performance | Resolution from 0.1 Pa |
Usb key | High power outputs | RS232, RS485, Can |
User-friendly interface | Easy to clean | 360° use |
Model | 0-0,2 bar | 0-0,5 bar | 0-1 bar | 0-2 bar | 0-3 bar | 0-6 bar |
Accuracy Dp | 1% RDG+3DGT | 1% RDG+3DGT | 1% RDG+3DGT | 1% RDG+3DGT | 1% RDG+3DGT | 1% RDG+3DGT |
Range of measurements Dp | 0-65 mbar | 0-65 mbar | 0-65 mbar | 0-65 mbar | 0-65 mbar | 0-65 mbar |
Resolution Dp | 0,001 mbar | 0,001 mbar | 0,001 mbar | 0,002 mbar |
0,005 mbar | 0,005 mbar |
Direct pressure accuracy | 1,5%FS | 1,5%FS | 1,5%FS | 1,5%FS | 1,5%FS | 1,5%FS |
Direct pressure measurement range | 0-FS | 0-FS | 0-FS | 0-FS | 0-FS | 0-FS |
Direct pressure resolution | 0,01 mbar | 0,01 mbar | 0,1 mbar | 0,1 mbar | 0,1 mbar | 0,1 mbar |
Accuracy measuring loss in cc/’ | 1%RDG+0,03cc/min | 1%RDG+0,03cc/min | 1%RDG+0,03cc/min | 1%RDG+0,03cc/min | 1%RDG+0,03cc/min | 1%RDG+0,03cc/min |
Measurement range in cc/’ | 0-10 cc/min | 0-10 cc/min | 0-10 cc/min | 0-10 cc/min | 0-10 cc/min | 0-10 cc/min |
Measured measurement resolution in cc/’ | 0,01 cc/min | 0,01 cc/min | 0,01 cc/min | 0,01 cc/min | 0,01 cc/min | 0,01 cc/min |
Accuracy measure volume in cc | - | - | - | - | - | - |
Volume range in cc | - | - | - | - | - | - |
Volume measurement resolution in cc | - | - | - | - | - | - |
measure unit | mbar, bar, psi, mmHg, mmH2O, Pa, HPa, cc/min, cc/h, pressure/s. | |||||
Dimensions | 180X160X200 mm | |||||
Weight | 5 kg | |||||
Display size | 320x240 pixel | |||||
Operating temperature range | 5-40 °C | |||||
RS232 ports | 2 | |||||
RS485 ports | 1 | |||||
“master” usb port | 1 | |||||
“slave” usb port | 1 | |||||
Ethernet port | - | |||||
I/O signals | Start, Stop, Filling, Test, Good, Reject, 3BCD | |||||
Auxiliaries I/O signals (optional) | - | |||||
Number of programs | 100 | |||||
Test archive memory | Standard | |||||
Password block | Yes | |||||
Program name | Yes, 8 characters | |||||
Reference normatives | EN 61010-1, EN61326-1 / EN61326/A1, EN61000-3-2 / EN61000-3-2/A14, EN61000-3-3 / EN61000-3-3/A1, EN61000-4-2 / EN61000-4-2/A1, EN61000-4-3 / EN61000-4-3/A1 / EN61000-4-3/A2, EN61000-4-4, EN61000-4-5, EN61000-4-11, EN1779 |