DIFFERENTIAL
  ABSOLUTE
  FLOW
  METROLOGY
  SOFTWARE
  DIFFERENTIAL
  ABSOLUTE
  FLOW
  METROLOGY
  SOFTWARE

T6060

DIFFERENTIAL ENTRY-LEVEL LEAK TESTER

FORTEST_T6060_Differential_Leak_Tester_Entry_Level_400x220px.jpg

So small, yet so powerful.
T6060 can count on a measurement resolution of 0.1 Pa to 1 bar (0.5 Pa to 6 bar) stable and noise-free, sharing a part of the measurement section implemented on the higher series T8000 and T9000.
Despite being designed as an entry-level tool, the measurement performance is absolutely comparable to those of the rest of the ForTest range.
 
 

   
Advanced measurement performance Resolution from 0.1 Pa

All the connections you need.
T6060 has a more limited port supply than its larger comrades, but is equally complete: a USB slave port, RS232, RS485 and Can bus.
The front panel has a master USB port assembled on it for connection to a USB key to save the tests conducted, backup/restore parameters and upgrade tool firmware.
The connection to thermal printers, barcode/data-matrix readers and markers takes place automatically using an internal menu.
 
     
Usb key High power outputs RS232, RS485, Can

Everything is where it should be.
Despite the compact dimensions which made use of more simplified menus necessary, the T6060 user interface was however designed to facilitate programming of the test parameters.
The front panel is made of a single sheet of tempered glass and aluminium, which makes it extremely easy to clean, making the T6060 suitable for use in the laboratory and on the production line.
The extensive internal menus are easy to understand and the graphic interface was designed to only display important information.
Everything is exactly where it should be.
 
     
User-friendly interface Easy to clean 360° use
 

Model 0-0,2 bar 0-0,5 bar 0-1 bar 0-2 bar 0-3 bar 0-6 bar
Accuracy Dp 1% RDG+3DGT 1% RDG+3DGT 1% RDG+3DGT 1% RDG+3DGT 1% RDG+3DGT 1% RDG+3DGT
Range of measurements Dp 0-65 mbar 0-65 mbar 0-65 mbar 0-65 mbar 0-65 mbar 0-65 mbar
Resolution Dp 0,001 mbar 0,001 mbar 0,001 mbar 0,002 mbar
 
0,005 mbar 0,005 mbar
Direct pressure accuracy 1,5%FS 1,5%FS 1,5%FS 1,5%FS 1,5%FS 1,5%FS
Direct pressure measurement range 0-FS 0-FS 0-FS 0-FS 0-FS 0-FS
Direct pressure resolution 0,01 mbar 0,01 mbar 0,1 mbar 0,1 mbar 0,1 mbar 0,1 mbar
Accuracy measuring loss in cc/’ 1%RDG+0,03cc/min 1%RDG+0,03cc/min 1%RDG+0,03cc/min 1%RDG+0,03cc/min 1%RDG+0,03cc/min 1%RDG+0,03cc/min
Measurement range in cc/’ 0-10 cc/min 0-10 cc/min 0-10 cc/min 0-10 cc/min 0-10 cc/min 0-10 cc/min
Measured measurement resolution in cc/’ 0,01 cc/min 0,01 cc/min 0,01 cc/min 0,01 cc/min 0,01 cc/min 0,01 cc/min
Accuracy measure volume in cc - - - - - -
Volume range in cc - - - - - -
Volume measurement resolution in cc - - - - - -
measure unit mbar, bar, psi, mmHg, mmH2O, Pa, HPa, cc/min, cc/h, pressure/s.
Dimensions 180X160X200 mm
Weight 5 kg
Display size 320x240 pixel
Operating temperature range 5-40 °C
RS232 ports 2
RS485 ports 1
“master” usb port 1
“slave” usb port 1
Ethernet port -
I/O signals Start, Stop, Filling, Test, Good, Reject, 3BCD
Auxiliaries I/O signals (optional) -
Number of programs 100
Test archive memory Standard
Password block Yes
Program name Yes, 8 characters
Reference normatives EN 61010-1, EN61326-1 / EN61326/A1, EN61000-3-2 / EN61000-3-2/A14, EN61000-3-3 / EN61000-3-3/A1, EN61000-4-2 / EN61000-4-2/A1, EN61000-4-3 / EN61000-4-3/A1 / EN61000-4-3/A2, EN61000-4-4, EN61000-4-5, EN61000-4-11, EN1779

  • External exhaust solenoid with protection filter
  • External start button
  • External start/abort pushbutton
  • External pushbutton 4 programs selection
  • Start pedal
  • Barcode reader
  • Adhesive label for printer 4500pcs
  • Aux signals extension cable
  • Venturi Vacuum generator
  • Air filter
  • M series manager software
  • TTY
  • Serial protocol
  • External 24 VDC power supply
  • PC serial cable owner - M Series
  • MIXER-07
  • Software Data Manager
  • Thermal printer with peel-off
  • Thermal printer without peel
  • Adapter cable AUX M Series - ET Series
  • Remote Start / Abort / Good / Reject
  • Software "Data Manager"
  • Air filter 5 micron

  • Pneumatics with micro electro valves - (STANDARD)
  • Frontal precision pressure regulator - (STANDARD)
  • Pneumatic module of remote measurements - (STANDARD)
  • Bi-manual logic Start Input
  • High resolution measure - (STANDARD)